Snow

Sanitary Napkin Disposal Machine

Sanitary napkin incinerator /Destroyer (Nano) is used for instant disposal of used napkins.Diaburn is used for instant disposal of used napkins in a very scientific and hygienic way.It is specially designed to destroy up to 30 napkins at a time.It is the best solution for destroying sanitary napkin and converting it to sterile ash.The Unit is Prepared with epoxy coated sheet metal and SS (Stainless Steel) for Good Look and to avoid Corrosion.It’s Automatic and Works on Domestic Electrical Supply.It is Idle for Sanitary Napkin Disposal. Our System for Sanitary Napkin Disposal is Eco- friendly, Helps to Avoid Drainage Line Chock-ups and having Very easy & Safe Operation..

Minimum Specification of Sanitary Pad Incinarator Machine

GENERAL Minimum Specification or Higher

Type Wall Mountable

Purpose - Burn used Sanitary Napkins to sterile ash and stop automatically

Calor - NA

Operation Mode Electrical operated, fully Automatic

Loading Type Front loading

Number of chambers One

Trap Door available Yes

All MS parts Powder coated Yes

Spare parts should be available for Minimum 5 years from date of supply - 1

All electrical parts are ISI Marked - Yes

DIMENSIONS OF MAIN UNIT

Thickness of thermal Insulation material (mm) - 25 millimeter

Thickness of MS/SS sheet of housing cabinet (external) (mm) - 1.0 -1.2 millimeter

Thickness of MS/SS sheet of burning chamber (internal) (mm) (Min) - 1 Millimiter

Machine Width(mm) - 200-300

Machine Depth (mm) - 200-300

Machine Hight{mm) - 200-500

Machine Weight(kg) - 8 to 15 KG

Door width{mm) - 75-100

Door height(mm) - 75-100

MATERIAL OF MACHINE UNIT

Material of Housing cabinet (External) - Mild Steel(CRCA) sheet

Material of Burning chamber (Internal) Mild Steel{(CRCA) sheet

Finish of MS parts of cabinet - Epoxy anti rust proof painting for superior finish

Material of Thermal Insulation High Density Ceramic Fiber sheet

CONSTRUCTIONAL FEATURES

Thermal insulation of burning chamber housed in outer chamber - Yes

Burning Chamber tray provided Yes

Emission Outlet pipe location - Top of machine

Means of connecting the unit outlet with flue gas emission pipe - Clamped

Type of door lock provided - Magnetic lock

CONTROL & FUNCTIONAL FEATURES

Temperature indicator provided - No

Timer provided - Yes

Auto cut-off temperature display - Yes

Minimum Burning temperature (degree C) - 800

Burning Capacity per day (Number of Napkins) - 80-100

Burning Capacity at a time {Number of Napkins) - 1t0 10

Burning time of full capacity Napkins/pads (minutes) - 10-15 minute {Max}

Installation, training, demonstration and plumbing - Yes

ELECTRICAL AND SAFETY FEATURES

Equipment ON/OFF indicator provided - Yes

Power supply - 230v +/-10%, 50Hz, Single phase, AC supply

Electrical Power Consumption(Watt) 500-1000

Minimum length of power chord to be supplied along 3 rab with machine (mtr) - 2 meter

Type of Heater - heater containing coil

Power saver (auto power cut-off) - Yes

Safety MCB provided (16A to 30A) - Yes

Protection against electric shock when checked as per 18:302-1/2008 - Yes

HV test at 1000 V rms for 1 Sec when tested as per 18:302-1/2008 - No breakdown shall occur during the test

SMOKE CONTROL UNIT (SCU)

Material of housing of Smcke Control Unit (SCU) - Mild Steel(CRCA) cabinet

Minimum length of flexible emission outlet pipe to be supplied along with machine (mtr) - 2

Cost of additional flexible emission outlet pipe, if required on actuals to be paid by the user - Yes

EMISSION STANDARD FOR SMOKE

Conformity to CPCB, Min of Environment & Forests standard, Solid Waste Management Rules (SW), 2016 - Yes

PACKING

Packing - Carton Box

CERTIFICATION

[

Submission of Test Report from Central Govt/CSIR Lab/NABL/ILAC accredited Lab specifically containing Electrical & Electronic parameters, Thermal insulation material of burning chamber in addition to declared specification parameter at time of supply - Yes

Submission Test Report for equipment for compliance of Flue gas emission and ash upon combustion of Sanitary Napkins/Pads to Central Pollution Control Board (CPCB) norms from NABL accredited lab/CSIR Lab at the time of supply - Yes

Certification Available - EU- CE

Certificate for Manufacturing premises available - ISO

Submission of all the certifications to the buyer along with supplies - Yes

PERFORMANCE REQUIREMENTS

Onsight Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue)